Electric-fan 5F
KFI performance-certified in Korea (use height up to 15 m).
Electric-fan rescue air cushions for floor categories 5F, 10F, 15F, 20F. Engine-powered models include a generator that powers electric blowers. Cylinder models are also available.

Floor labels are catalog categories. Dimensions are length × width × height.
Source: Product catalog / Product specifications| Floor category | 5F | 10F | 15F | 20F |
|---|---|---|---|---|
| Size (L × W × H) | 6 × 4 × 2.1 m | 7 × 4.8 × 2.5 m | 8 × 6 × 2.8 m | 10 × 7 × 2.8 m |
| Product weight | 60 kg | 100 kg | 115 kg | 145 kg |
| Setup time | 55 s | 120 s | 180 s | 180 s |
| Evacuation interval | 18 s | 25 s | 35 s | 45 s |
| Blowers | 1 Large | 2 Standard | 2 Standard | 2 Large |
TNT sends the recommended blower specification (airflow, static pressure and power supply) with the quotation. The blower can then be sourced locally to match your power supply.
Power supply: Single-phase 220 V, 50/60 Hz (three-phase 220/380 V available)
| Specification | Standard | Large |
|---|---|---|
| Power consumption (50 / 60 Hz) | 450 / 600 W | 625 / 960 W |
| Maximum airflow | 53 / 61 m³/min | 105 / 125 m³/min |
| Maximum static pressure | 440 / 590 Pa | 640 / 880 Pa |
| Weight | 14 kg | 16.5 kg |
Values are per blower. Paired values are shown in 50 / 60 Hz order.
| Minimum generator output | 2.6 kW |
|---|---|
| 20F product weight | 150 kg |
| Setup time (10F) | 120 s |
| Setup time (15F) | 180 s |
| Setup time (20F) | 180 s |
Dimensions follow the electric-fan table. A generator is included and powers the electric blowers.
Floor labels are catalog categories. Dimensions are length × width × height.
Source: Product catalog / Product drawingCertified model: Cylinder lightweight (3.5 × 3.5 × 1.7 m class). This size is not listed in the table below.
Square as standard. An octagonal version and custom shapes are available on request.

| Floor category | 5F | 10F | 15F | 20F |
|---|---|---|---|---|
| Size (L × W × H) | 4 × 4 × 2 m | 7 × 4.8 × 2.5 m | 8 × 6 × 3 m | 10 × 7 × 3 m |
| Product weight | 70 kg | 120 kg | 170 kg | 220 kg |
| Setup time | 40 s | 40 s | 70 s | 120 s |
| Evacuation interval | 10 s | 25 s | 35 s | 50 s |
| Floor category | Box size (L × W × H) | Box weight |
|---|---|---|
| 5F | 100 × 60 × 30 cm | 60 kg |
| 10F | 110 × 70 × 40 cm | 100 kg |
| 15F | 120 × 70 × 45 cm | 115 kg |
| 20F | 120 × 70 × 50 cm | 145 kg |
| Size | Box size (L × W × H) | Box weight |
|---|---|---|
| Standard | 41 × 36 × 45 cm | 14.5 kg |
| Large | 48 × 40 × 34 cm | 17 kg |
Box sizes can vary with components and order.
2-year warranty. In Korea, replacement is recommended every 7 years.
| Material | Tarpaulin (polyester) |
|---|
The high-contrast TNT landing target is printed as standard without a logo; the TNT logo is on the side label.
KFI performance-certified in Korea (use height up to 15 m).
KFI performance-certified in Korea (use height up to 15 m).
55 to 180 s across the electric-fan range.
18 to 45 s across the electric-fan range.
TNT sends the recommended blower specification (airflow, static pressure and power supply) with the quotation. The blower can then be sourced locally to match your power supply.
Certification details for electric-fan 5F and the cylinder lightweight class are provided during quotation.
Send your inquiry by email or the form below.
Send the floor category or drop height, quantity, destination country and port, and local power supply details.
TNT replies by email with a quotation and specification sheet.
TNT replies by email with a quotation and specification sheet.